3300 XL 8 mm unarmored probe with 0.8 in unthreaded length, 2.4 in case and 1 m standard cable.
| Field | Exact selection |
|---|---|
| Part number | 330101-08-24-10-02-00 |
| Product type | 3300 XL 8 mm probe |
| Thread | 3/8-24 UNF |
| Unthreaded length | 0.8 in |
| Overall case length | 2.4 in |
| Length | 1.0 m (3.3 ft) |
| Construction | Without armor |
| Termination | Miniature coaxial ClickLoc connector, standard cable |
| Approval option | No approvals |
Radial vibration, axial position and Keyphasor phase-reference measurements.
Before installation? Confirm the exact model, mating components and required length.
Unstable signal? Inspect routing, termination, grounding and mechanical strain.
Visible damage? Remove the component from service and evaluate replacement.
The 330101-08-24-10-02-00 is a compact 3300 XL 8 mm probe configuration intended for installations that require a short unthreaded section, a defined case length and a one-metre integral cable. The complete suffix should be checked as one ordering identity because probe body geometry, case construction, cable length and connector arrangement determine whether the probe will fit the existing mounting location.
Typical machinery-monitoring work includes radial vibration and shaft-position measurements where an 8 mm proximity probe is installed through a compatible bracket, probe housing or machine case. The short unthreaded tip section supports installations in which the sensing end must reach the target while the threaded body remains available for secure positioning.
For a quotation, provide the full model, quantity, installed system length and any available photos of the existing probe label and connector. This allows the suffix, mounting geometry and system compatibility to be reviewed before dispatch.
Can only the probe be replaced? A probe can be replaced within a compatible system, but the full probe, extension cable and Proximitor Sensor combination must remain electrically matched.
What should be checked first during troubleshooting? Inspect connector cleanliness, cable condition, mounting security, probe gap and the associated channel wiring before changing the probe position.
| Stage | Service |
|---|---|
| Condition | Brand-new unit |
| Warranty | 12 months under written quotation terms |
| Technical check | Full part number, application and compatibility review |
| Packing | Protective export packing and tracked dispatch |
| Dispatch & returns | Tracking and return authorization under written terms |
| 330104-00-05-05-02-00 | 330130-040-01-00 | 330180-91-00 | 330180-92-05 | 3500/15 |
| 3500/22M | 3500/32M | 3500/42M | 3500/53 | 330851-04-00-27-10-01-00 |
| 330876-01-10-00-00 | 330878-X0-00 MOD 177889-01 | 792414506-04 | SDCS-CON-1 | TB853 3BSE057022R1 |
| 1746-OB16E | 1746-A7 | 1756-ENBT | 1756-L63 | 1769-PA2 |
| 6ES7315-2AG10-0AB0 | 6ES7321-1BL00-0AA0 | 6ES7322-1BL00-0AA0 | 6ES7153-2BA02-0XB0 | 6ES7414-3XM05-0AB0 |
| 6ES7134-4GB11-0AB0 | 6GK7343-1EX30-0XE0 | 6ES7953-8LJ30-0AA0 | IS200TRLYH1B | IS220PAICH1B |
| IS200TBCIH1B | IC695CPU310 | IC200MDL750 | BMXXBP0400 | BMXP342020 |
| 140CPU65150 | 9905-969 | 9905-971 | 9907-164 | 5466-1035 |
| 5466-258 | 5466-409 | 5466-425 | 5453-279 | 5453-203 |
| ADV551-P60 | PW441-11 | CC-PAIH01 | 3708E | F7131 |