330105-02-12-10-02-05 is a Bently Nevada 3300 XL 8mm reverse mount proximity probe featuring an integrated 3/8-24 UNF thread structure. Fully compatible with bracket installations, this unit works seamlessly with protective housings to deliver flexible industrial sensor placement and stable industrial network communication.
Specifications
Unthreaded Length Option:20 mm
Overall Case Length Option:100 mm
Total Length Option:1.0 meter (3.3 feet)
Connector and Cable-Type Option:Miniature ClickLoc coaxial connector
Agency Approval Option:CSA, ATEX, IECEx Approvals
Dimensions:1.2x1x112cm
Weight:0.05kg
Enviromental Strength
-
Extended Temperature Capability: Supports ETR options up to 218°C (425°F) for high-heat applications.
-
FluidLoc Leak Prevention: Prevents oil and liquid leakage through the cable interior, protecting machine integrity.
-
Corrosion-Resistant Connectors: Gold-plated ClickLoc connectors resist corrosion and ensure secure connections in wet environments.
-
High Mechanical Strength: Patented CableLoc design provides 330 N (75 lbf) pull strength for durability under stress.
-
RFI/EMI Immunity: Reliable operation in fiberglass housings without shielded conduit, meeting CE mark standards.
-
Interchangeable Compatibility: Fully interchangeable with other 3300 XL components, simplifying field replacements and reducing downtime.
System Compatibility & Alternatives
- System Compatibility:
Fully compatible with Bently Nevada 3300 XL Proximitor Sensors and 3300 XL standard extension cables. It is fully interchangeable with older non-XL 3300 series 5mm and 8mm transducer systems, maintaining backward compatibility compliant with API 670 standards. - Alternative Model & Differences:
The corresponding alternative configuration within the metric series is catalog number 330106-05-30-10-02-05. - The Difference: The 330105-02-12-10-02-05 uses an English standard 3/8-24 UNF-2A thread layout with fixed structural length options (0.2 in unthreaded, 1.2 in case length) and a 7/16-inch hexagonal body size. The 330106 variant uses an M10x1 metric thread structure with customized options (5mm unthreaded, 30mm case length) and a matching M10 hexagonal body profile for metric machines. Neither variant supports flexible stainless steel armor or integrated connector protector options due to their specific reverse-mount mechanical design.
Ordering Information
|
Model Option Block |
Parameter Selection |
Decoded Hardware Specifications |
|
Base Model |
330105 |
3300 XL 8 mm Reverse Mount Probe, 3/8-24 UNF threads |
|
A: Unthreaded Length |
02 |
0.2 in. unthreaded length configuration |
|
B: Overall Case Length |
12 |
1.2 in. overall case length configuration |
|
C: Total Length |
10 |
1.0 meter (3.3 feet) integral cable length |
|
D: Connector/Cable Type |
02 |
Miniature coaxial ClickLoc connector, standard cable |
|
E: Agency Approval |
05 |
CSA, ATEX, IECEx hazardous area certifications |
Installation & Troubleshooting FAQ
Q1: What are the torque limits for fastening this reverse mount probe housing?
A: The maximum rated installation torque for this probe case structure is 22.6 N•m (200 in•lbf). For standard plant setups, the recommended tightening torque is 7.5 N•m (66 in•lbf). Tightening beyond the maximum limits will deform the structural body housing and result in thread binding.
Q2: Why are stainless steel armor options unavailable for this specific configuration?
A: The reverse mount design is specifically engineered to be inserted through a protective sleeve or internal bracket channel inside the machine casing. Because the entire length of the cable and body stays protected inside the mounting sleeve matrix, external abrasive forces are avoided. This eliminates the need for bulky stainless steel armor profiles.
Q3: How do I choose between standard silicone tape and a connector protector for this setup?
A: This specific unarmored probe comes with standard ClickLoc connectors without an installed protector. For field connections inside junction boxes, wrapping with self-fusing silicone tape is ideal. However, do not use silicone tape if the junction point is exposed to turbine oil washdowns, as chemical degradation can compromise electrical insulation.
Q4: My system calibration curve looks distorted after mounting the probe inside a sleeve. What is the cause?
A: This is typically caused by inadequate clearance inside the probe sleeve or mounting bracket tip opening. If the metallic counterbore or housing diameter surrounding the 8mm tip is too narrow, an electromagnetic "Side Effect" occurs. To prevent this signal distortion, ensure the internal counterbore diameter provides a minimum clearance width of 24mm.
Accessories
| 141078 | 3300 XL 8 mm and 3300 5 mm Proximity Transducer System Manual. |
| 175751 | 3300 XL Multi-Purpose Stainless Steel Housing. 12”x12”x6”. Can hold up to 8 Proximitor Sensors in a DIN-mount configuration or 6 Proximitor Sensors in a panelmount configuration. (Available with ATEX Zone 0 and Zone 1 certifications.) |
| 176467 | 3300 XL Multi-Purpose Stainless Steel Housing. 12”x8”x6”. Can hold up to 4 3300XL Proximitor Sensors in both DIN-mount and panel-mount configurations. (Available with ATEX Zone 0 and Zone 1 certifications.) |
| 330181 | 3300 XL Multi-Purpose Stainless Steel Housing. 13”x9.5”x7”. Can hold up to 8 Proximitor sensors in a DIN-mount configuration or 6 Proximitor Sensors in a panelmount configuration. Primarily used by customers requiring hazardous area approvals fro their installations. Available with ATEX Zone 0 and Zone 1 and North American Division 1 and Division 2 certifications. |
| 02120015 | Bulk field wire. 1.0 mm2 (18 AWG), 3 conductor, twisted, shielded cable with drain wire. Specify length in feet. |
| 138492-01 | Replacement panel-mount mounting pad. |
| 138493-01 | Replacement DIN-mount mounting pad. |
| 148722-01 | 3300 XL test plug. The 3300 XL Test Plug contains 3 small test pins attached to 3 color-coded 1-meter wires, each terminated in a banana plug. The 3-pin adapter plugs into the test pin holes on 3300 XL-style Proximitor sensors. You can use this test plug to check the performance of the Proximitor sensor from the test pin holes in the terminal strip without removing the field wiring. |
| 04310310 | 3300 XL Proximitor Sensor panelmount screw. One 6-32 UNC thread forming mounting screw. Four screws are required for each Proximitor sensor. (Screws supplied standard with Proximitor housings [3300 XL panel-mount option]). |
| 03200006 | Silicone self-fusing tape. A 9.1- meter (10-yard) roll of silicone tape to protect connectors. This tape is easy to install and provides excellent electrical isolation and protection from the environment. We do not recommend using this tape inside the casing of the machine. |
| 40113-02 | Connector Protector Kit. Connector Protector Kit for 3300 XL 8 mm probes and extension cables, including connector protectors and installation tools. |
| 136536-01 | Connector protector adapter. This allows you to use connector protector installation tools manufactured prior to 1998 with 75Ω ClickLoc connectors. |
| 40180-02 | Connector protectors. Package contains 10 pairs of connector protectors for 3300 XL 8 mm probes and extension cables. |
| 03839410 | 75Ω triaxial male connector protector. Male connector protectors install onto the extension cable and attach to the female connector protector on the probe, providing environmental protection of connectors. |
| 03839420 | 75Ω triaxial female connector protector. Female connector protectors install onto the probe lead and attach to the male connector protector on the extension cable, providing environmental protection of connectors. You can also place the connector protector onto the extension cable to slide over the connection to the Proximitor sensor to protect that connection from the environment. |
| 04301007 | 3/8-24 probe lock nut with safety wire holes. Single probe lock nut with 2 holes drilled through the nut in order to secure the lock nut in place with safety wire. |
| 04301008 | M10 x 1 probe lock nut with safety wire holes. Single probe lock nut with 2 holes drilled through the nut in order to secure the lock nut in place with safety wire. |
| 330153-01 | 3300 XL connector kit. Used on 3300 XL 8 mm probes and extension cables. Contains 1 pair each of male and female ClickLoc connectors, 2 colorcoded sleeves, 2 pieces of slit FEP tubing, and 1 strip of silicone tape. |
| 330153-09 | 3300 XL ETR Connector Kit. Used on ETR 3300 XL 8mm probes and 3300 ETR XL extension cables. Contains one pair of male and female ClickLoc connectors, two color-coded sleeves, two pieces of high temperature slit FEP tubing, and one strip of silicon tape. |
| 163356 | Connector Crimp Tool Kit. Includes 1 set of multiconnector inserts and connector installation instructions. Compatible only with 330153 connector kits or with probes shipped in 2003 or later with ClickLoc connectors uninstalled. Supplied with carrying case. |




For the quick assistance message us on WhatsApp at 