330101-30-63-15-02-CN is a Bently Nevada eddy current proximity probe featuring an extended 3.0-inch unthreaded sleeve section. Fully compatible with deep machinery housings, this unit works seamlessly with heavy-duty protective brackets to deliver flexible gap adjustment capabilities and stable industrial network communication.
Specifications
Unthreaded Length Option:8.8 in
Overall Case Length Option:6.3 in
Total Length Option:1.5 meter (4.9 feet)
Connector and Cable-Type Option:Miniature coaxial ClickLoc connector, standard cable
Dimensions:22x20x2cm
Weight:0.12kg
Enviromental Strength
-
Extended Temperature Rating: Supports ETR probes up to 218°C (425°F) and cables up to 260°C (500°F) for high-heat applications.
-
Superior RFI/EMI Immunity: Operates reliably in fiberglass housings without shielded conduit, meeting CE mark requirements.
-
FluidLoc Leak Prevention: Optional cable construction prevents oil and liquid leakage through the cable interior, protecting machinery.
-
Corrosion-Resistant Connectors: Gold-plated ClickLoc connectors resist corrosion and maintain secure connections in wet environments.
-
High Mechanical Strength: Patented CableLoc design provides 330 N (75 lbf) pull strength, ensuring durability under physical stress.
-
Flexible Mounting Isolation: Proximitor sensor base offers electrical isolation, eliminating separate isolator plates in panel or DIN-rail setups.
Ordering Information
|
Model Option Block |
Parameter Selection |
Decoded Hardware Specifications |
|
Base Model |
330101 |
3300 XL 8 mm Probe, 3/8-24 UNF thread, without armor |
|
A: Unthreaded Length |
30 |
3.0 inches unthreaded case section length |
|
B: Overall Case Length |
63 |
6.3 inches overall structural case length |
|
C: Total Length |
15 |
1.5 meters (4.9 feet) integral cable length |
|
D: Connector/Cable Type |
02 |
Miniature coaxial ClickLoc connector, standard cable |
|
E: Agency Approval |
CN |
Regional localized safety certification standard approvals |
Specific Application
- Radial vibration measuring inside thick-walled bearing casings where threads must bypass outer insulation blankets.
- Axial position calibration loops requiring a long structural shank body to traverse external mounting gland configurations.
- Machinery safety setups needing localized industrial certification standards inside regional factory infrastructures.
Installation & Troubleshooting FAQ
Q1: What are the torque limits for securing this long-case forward mounted probe?
A: The maximum rated installation torque for this 3/8-24 UNF case structure is 33.9 N•m (300 in•lbf). For standard field setups, the recommended tightening torque is 11.2 N•m (100 in•lbf). If you are tightening down exclusively into the first three threads of the housing hole, drop your targets to a maximum of 22.6 N•m (200 in•lbf) to prevent structural distortion.
Q2: Why does this configuration feature a long 3.0-inch unthreaded sleeve section?
A: The extended unthreaded option prevents thread binding when routing through thick outer machine brackets or heavy housing walls. It allows field maintenance teams to slide the main probe barrel deep inside a smooth bore before making mechanical contact with the internal thread matrix, facilitating easier physical positioning.
Q3: How do I handle an unstable signal path when routing this unarmored triaxial cable?
A: This unarmored probe relies on its internal FEP insulating jacket for general protection. If you are routing through areas with moving components or sharp structural edges, you must house the cable inside an external rigid or flexible conduit system. Ensure the path respects the minimum cable bend radius of 25.4 mm (1.0 inch) to preserve internal wire insulation.
Q4: Can I splice or solder this 1.5-meter integral cable if it gets accidentally cut during installation?
A: No, proximity probe cables cannot be spliced or repaired using standard field wire methods. The cable is a matched 75Ω triaxial transmission line with precise nominal DC resistance characteristics. Any standard field splice will introduce major impedance mismatches and distort the Proximitor's calibration curve, requiring a complete replacement of the core probe hardware.
Accessories
| 141078 | 3300 XL 8 mm and 3300 5 mm Proximity Transducer System Manual. |
| 175751 | 3300 XL Multi-Purpose Stainless Steel Housing. 12”x12”x6”. Can hold up to 8 Proximitor Sensors in a DIN-mount configuration or 6 Proximitor Sensors in a panelmount configuration. (Available with ATEX Zone 0 and Zone 1 certifications.) |
| 176467 | 3300 XL Multi-Purpose Stainless Steel Housing. 12”x8”x6”. Can hold up to 4 3300XL Proximitor Sensors in both DIN-mount and panel-mount configurations. (Available with ATEX Zone 0 and Zone 1 certifications.) |
| 330181 | 3300 XL Multi-Purpose Stainless Steel Housing. 13”x9.5”x7”. Can hold up to 8 Proximitor sensors in a DIN-mount configuration or 6 Proximitor Sensors in a panelmount configuration. Primarily used by customers requiring hazardous area approvals fro their installations. Available with ATEX Zone 0 and Zone 1 and North American Division 1 and Division 2 certifications. |
| 02120015 | Bulk field wire. 1.0 mm2 (18 AWG), 3 conductor, twisted, shielded cable with drain wire. Specify length in feet. |
| 138492-01 | Replacement panel-mount mounting pad. |
| 138493-01 | Replacement DIN-mount mounting pad. |
| 148722-01 | 3300 XL test plug. The 3300 XL Test Plug contains 3 small test pins attached to 3 color-coded 1-meter wires, each terminated in a banana plug. The 3-pin adapter plugs into the test pin holes on 3300 XL-style Proximitor sensors. You can use this test plug to check the performance of the Proximitor sensor from the test pin holes in the terminal strip without removing the field wiring. |
| 04310310 | 3300 XL Proximitor Sensor panelmount screw. One 6-32 UNC thread forming mounting screw. Four screws are required for each Proximitor sensor. (Screws supplied standard with Proximitor housings [3300 XL panel-mount option]). |
| 03200006 | Silicone self-fusing tape. A 9.1- meter (10-yard) roll of silicone tape to protect connectors. This tape is easy to install and provides excellent electrical isolation and protection from the environment. We do not recommend using this tape inside the casing of the machine. |
| 40113-02 | Connector Protector Kit. Connector Protector Kit for 3300 XL 8 mm probes and extension cables, including connector protectors and installation tools. |
| 136536-01 | Connector protector adapter. This allows you to use connector protector installation tools manufactured prior to 1998 with 75Ω ClickLoc connectors. |
| 40180-02 | Connector protectors. Package contains 10 pairs of connector protectors for 3300 XL 8 mm probes and extension cables. |
| 03839410 | 75Ω triaxial male connector protector. Male connector protectors install onto the extension cable and attach to the female connector protector on the probe, providing environmental protection of connectors. |
| 03839420 | 75Ω triaxial female connector protector. Female connector protectors install onto the probe lead and attach to the male connector protector on the extension cable, providing environmental protection of connectors. You can also place the connector protector onto the extension cable to slide over the connection to the Proximitor sensor to protect that connection from the environment. |
| 04301007 | 3/8-24 probe lock nut with safety wire holes. Single probe lock nut with 2 holes drilled through the nut in order to secure the lock nut in place with safety wire. |
| 04301008 | M10 x 1 probe lock nut with safety wire holes. Single probe lock nut with 2 holes drilled through the nut in order to secure the lock nut in place with safety wire. |
| 330153-01 | 3300 XL connector kit. Used on 3300 XL 8 mm probes and extension cables. Contains 1 pair each of male and female ClickLoc connectors, 2 colorcoded sleeves, 2 pieces of slit FEP tubing, and 1 strip of silicone tape. |
| 330153-09 | 3300 XL ETR Connector Kit. Used on ETR 3300 XL 8mm probes and 3300 ETR XL extension cables. Contains one pair of male and female ClickLoc connectors, two color-coded sleeves, two pieces of high temperature slit FEP tubing, and one strip of silicon tape. |
| 163356 | Connector Crimp Tool Kit. Includes 1 set of multiconnector inserts and connector installation instructions. Compatible only with 330153 connector kits or with probes shipped in 2003 or later with ClickLoc connectors uninstalled. Supplied with carrying case. |




For the quick assistance message us on WhatsApp at 