Verified product identity, system fit and procurement checks
Product Overview
The Siemens 6GT2811-6BC10-2AA0 is the CMIIT regulatory variant of the SIMATIC RF600 RF610R fixed UHF RFID reader. Siemens documentation identifies an integrated antenna, one Ethernet/PROFINET M12 interface, 24 V DC supply, IP67 protection and an operating temperature range from -25 °C to +55 °C. The reader connects directly to supported industrial networks for identification, tracking and material-flow applications. Siemens also lists this exact order number in the RF600 firmware V4.0 hardware support package for STEP 7 V16 Update 5. Procurement should verify the full suffix, regulatory region, firmware, network configuration, connector, power supply and project software.
Commercial Status
Product Condition
Original new
Availability
In stock
Warranty
With 1 year warranty
Shipping
Worldwide shipping options available
Condition, availability and warranty are Stockoems commercial information, not manufacturer commitments.
Verified Technical Data
Manufacturer
Siemens
Complete Part Number
6GT2811-6BC10-2AA0
Product Type
SIMATIC RF600 RF610R fixed UHF RFID reader
Product Family
RF610R
Regulatory Variant
CMIIT
Antenna
1 integrated antenna
Network Interface
1 x Ethernet / PROFINET M12
Rated Supply Voltage
24 V DC
Degree of Protection
IP67
Operating Temperature
-25 to +55 °C
Firmware Engineering Reference
RF600 firmware V4.0
TIA Portal Requirement
HSP 0376 with STEP 7 V16 Update 5 for firmware V4.0
Country of Origin
Germany
System Fit and Applications
System Fit
SIMATIC RF600 UHF RFID installations using the exact RF610R CMIIT regional variant
System Role
Fixed reader for identifying compatible UHF transponders through its integrated antenna
Typical Applications
Material tracking, production identification, logistics checkpoints, workpiece routing and maintenance replacement
Critical Checks
Complete suffix, CMIIT region, firmware, UHF transponder standard, read-zone requirements, PROFINET or Ethernet settings, M12 connector, 24 V DC supply and project software
Compatibility and Procurement Checks
Confirm the complete order number and CMIIT suffix, firmware version, regional radio approval, supported UHF transponders, required read zone, Ethernet or PROFINET configuration, M12 cabling, 24 V DC supply, mounting position and TIA Portal hardware support package. ETSI and FCC RF610R suffixes are different regulated variants and must not be substituted without approval review.
Lifecycle Note
The reviewed Siemens exact-model system documentation confirms the CMIIT variant and technical configuration but does not state a lifecycle classification. Procurement should consult the current Siemens lifecycle record for 6GT2811-6BC10-2AA0 and verify firmware, regional approval, network settings and project software before ordering.
Frequently Asked Questions
What does 6GT2811-6BC10-2AA0 identify?
It identifies the Siemens SIMATIC RF600 RF610R fixed UHF RFID reader in the CMIIT regulatory variant.
Which antenna configuration is provided?
Siemens documentation specifies one integrated antenna for the RF610R reader.
Which network interface is available?
The reader provides one Ethernet/PROFINET interface with an M12 connection.
Which electrical and environmental details should be checked?
Verify the 24 V DC supply, IP67 protection, -25 °C to +55 °C environment and mounting conditions.
Which engineering software requirement is documented?
For RF600 firmware V4.0, Siemens lists HSP 0376 with STEP 7 V16 Update 5.
What should be reviewed before replacement?
Check the CMIIT suffix, firmware, radio approval, transponders, read zone, M12 cabling, network settings and project software.
Request Product Review
Send us the complete part number, required quantity, destination country and product label photos. Our team will check availability, condition, compatibility requirements and shipping options.
Structured verification, inspection, packaging and after-sales coordination for 6GT2811-6BC10-2AA0
Service Workflow
Stockoems coordinates commercial and technical checks for Siemens 6GT2811-6BC10-2AA0. The workflow starts with the complete identifier, installed-system role and label evidence, then reviews condition, configuration requirements and shipping documentation without promising unverified compatibility or delivery dates.
Model and Suffix Verification
Compare the complete 6GT2811-6BC10-2AA0 identifier and supplied nameplate against the purchase request.
Condition Confirmation
Review visible condition, seals, connectors, packaging and available inspection evidence.
Technical Compatibility Review
Check the installed system, hardware or firmware revision, interfaces, software and project configuration.
Product and Label Photos
Coordinate clear photographs of the unit, manufacturer label, connectors and packaging where available.
Quality Review
Check item identity and visible condition against the written order details before dispatch preparation.
Protective Packaging
Use appropriate anti-static and impact-protection methods for industrial electronic equipment.
Worldwide Shipping
Coordinate suitable international shipping options after destination and order review.
Shipment Tracking
Provide tracking details after carrier collection and document processing.
Customs Documentation
Prepare commercial shipping documents based on the reviewed order and destination requirements.
Written Warranty Terms
Confirm Stockoems warranty scope and applicable terms in writing with the order.
Return Authorization Process
Use a documented review and authorization process before any return shipment.
After-Sales Response
Coordinate order records, photographs and technical context for efficient follow-up communication.
Our Working Environment
Order and model verification by our office team.Technical documentation and compatibility coordination.Inspection records, packaging and shipment documentation.
Inspection and Documentation
For 6GT2811-6BC10-2AA0, purchasers should retain the quotation, complete identifier, condition statement, label evidence and agreed commercial terms. Engineers should compare the installed hardware, firmware, interfaces, software and project configuration before replacement. Protective packaging, shipping documents and tracking are coordinated after order review.
Written warranty terms, return authorization steps and after-sales contact details are supplied through the commercial process so purchasing and engineering teams have a traceable record.
Supplier Qualification FAQ
How can end users identify a qualified industrial automation source?
Look for complete order-code handling, transparent condition descriptions, traceable communication, clear inspection evidence, written terms and a defined after-sales process.
Which documents, labels and commercial terms should buyers verify?
Verify the quotation, invoice details, full identifier, manufacturer label photographs, condition statement, warranty scope, shipping terms and return authorization process.
How should engineers confirm model, firmware, interfaces and compatibility?
Compare the complete identifier, installed revisions, connectors, electrical requirements, software and project configuration against the existing system documentation.
What warning signs should purchasing teams watch for?
Incomplete identifiers, refusal to provide label images, conflicting technical descriptions, unrealistic delivery promises and no documented return process are important risk signals.
Request Service Support
Send us the complete part number, required quantity, destination country and product label photos. Our team will check availability, condition, compatibility requirements and shipping options.