CPU 413-1 with MPI interface for legacy S7-400 automation systems
The Siemens 6ES7413-1XG01-0AB0 is a SIMATIC S7-400 CPU 413-1 central processing unit. Siemens firmware and compatibility documentation confirms this exact order number for the CPU 413 family.
It executes the controller program in an S7-400 rack and communicates through its integrated MPI interface. Hardware release, firmware, memory card, communication processors and the archived STEP 7 project must be checked before replacement.
| Lifecycle | Discontinued |
| Official confirmation | Siemens documentation identifies 6ES7413-1XG01-0AB0 as a discontinued CPU 413-1 and continues to list it in compatibility and firmware references. |
| Successor | No exact drop-in successor was confirmed in the reviewed official documents. |
| Supply approach | Verify order number, hardware release, firmware, memory card, rack compatibility, project backup, condition and warranty. |
| Parameter | Official specification | Procurement significance |
|---|---|---|
| Product type | SIMATIC S7-400 CPU 413-1 | Match the exact CPU 413-1 order number and hardware release. |
| Working memory | 72 KB | Confirm the original project fits the CPU memory resources. |
| Integrated interface | MPI | Check programming, HMI and peer communication topology. |
| Firmware reference | A9 in Siemens firmware update documentation | Verify firmware before installing a field replacement. |
| Controller platform | SIMATIC S7-400 modular automation system | Confirm rack, power supply and backplane compatibility. |
| Engineering environment | Legacy STEP 7 project environment | Retain an accessible project backup and required software. |
| Memory media | S7 memory card selected for the installed firmware and program | Confirm card type, capacity and existing program contents. |
| Communication expansion | Compatible S7-400 communication processors depend on CPU release | Check CP model, firmware and Siemens compatibility tables. |
| Supply interface | Powered through the S7-400 backplane | Inspect rack and power-supply health before replacement. |
| Lifecycle context | Discontinued CPU type in Siemens documentation | Plan spare strategy and migration without assuming plug-in equivalence. |
Maintain an installed S7-400 CPU 413-1 station when the original architecture must remain in service.
Replace a failed CPU only after matching hardware release, firmware, memory card and archived project.
Document I/O, communication processors and software dependencies before redesigning the controller platform.
Confirm 6ES7413-1XG01-0AB0 and do not substitute another CPU 413 or CPU 414 revision by appearance.
Record the front label, hardware release, firmware level and memory-card data from the installed CPU.
Verify STEP 7 version, archived project, passwords, communication processors and network configuration.
Confirm CPU condition, memory card inclusion, connector covers, testing, warranty and destination.
Siemens identifies 6ES7413-1XG01-0AB0 as a discontinued CPU 413-1. Current compatibility documents still list the exact order number, but this does not establish interchangeability with later CPU revisions; project and hardware checks remain mandatory.
It is a Siemens SIMATIC S7-400 CPU 413-1 central processing unit with an integrated MPI interface.
Siemens documentation describes this CPU type as discontinued.
Not automatically. Hardware release, firmware, memory, project and communication compatibility must be checked.
Retain the STEP 7 project, hardware configuration, communication settings and memory-card contents.
Provide the full order number, hardware release, firmware, memory card, condition, quantity and destination.
Request stock verification, hardware and STEP 7 compatibility checks, global delivery options and warranty details.
A structured path from CPU identity verification and project compatibility review to protected global delivery.
Order number, hardware release, firmware, memory card and visible condition are checked against the request.
Rack, STEP 7 project, communication processors and interface requirements are documented.
Packing, freight route, export documentation, warranty scope and destination details are coordinated.
| Stage | What we verify | Buyer input |
|---|---|---|
| Before quote | Exact article, availability, condition and included memory media | Quantity, country and delivery destination |
| Compatibility review | Hardware release, firmware, rack, project and communication compatibility | Rack model, STEP 7 project and installed communication processors |
| Before shipment | CPU label, interfaces, housing, packing and documents | Receiving requirements and contact details |
Send 6ES7413-1XG01-0AB0, the hardware release, firmware, rack and STEP 7 project requirements for a focused response.
Provide the model, quantity, condition preference and destination so the correct service scope can be prepared.
| 6ES7315-2AH14-0AB0 | 1756-L83E | 3BSE018161R1 |
| CC-PAIH01 | KJ3001X1-BA1 | AAI141-S00 |
| 3500/15 | BMXP342020 | KFD2-STC4-Ex1 |
| IB IL 24 DI 16 | CX5130-0125 | IC695CPE310 |
| F8650X | FBM201 | 6ES7134-6GF00-0AA1 |
| 1756-IB16 | 3BSE020514R1 | CC-PAOX01 |
| KJ3222X1-BA1 | AAI543-S00 | 3500/22M |
| BMXDDI1602 | KFD2-SR2-Ex2.W | IB IL 24 DO 16 |
| EL1008 | IC695ETM001 | F6217 |
| FBM207 | 6GK5208-0BA10-2AA3 | 1756-EN2T |
| 3BSE013252R1 | CC-PDIL01 | VE4003S2B1 |
| ADV151-P00 | 3500/32M | BMXDDO1602 |
| KCD2-SCD-Ex1 | FL SWITCH 1008N | EL2008 |
| IC694MDL645 | F3330 | FBM217 |
| 6AV2124-0MC01-0AX0 | 1794-AENTR | 3BSE041882R1 |
| CC-PCNT01 | KJ2003X1-BB1 | AFV10D-S41201 |
| 3500/42M | 140CPU67160 | NJ2-V3-N |
| QUINT4-PS/1AC/24DC/10 | EL3064 | IS220PAICH1A |
| X-CPU 01 | P0926JM | 6SL3210-1KE21-7UF1 |
| 2711P-T10C22D9P | 3BSE008538R1 | 51304540-100 |
Share the installed model, network architecture and application constraints before selecting any alternative.
List the required models, quantities and application constraints. Every alternative must be checked independently before purchase.