330102-00-20-05-02-00 is a Bently Nevada 3300 XL 8mm proximity probe featuring a stainless steel armored cable. Fully compliant with API 670 standards, this unit works seamlessly with 3300 XL Proximitor sensors to deliver an 80-mil linear measuring range and stable machine-level vibration communication under high-abrasion environments.
Specifications
Unthreaded Length Option:0.0 in
Overall Case Length Option:2.0 in
Total Length Option:0.5 meter (1.6 feet)
Connector and Cable-Type Option:Miniature coaxial ClickLoc connector, standard cable
Agency Approval Option:Not required
Dimensions:1.5x1.2x120cm,0.15kg
Weight:0.15kg
Application
This armored 8 mm proximity probe is primarily used for radial vibration, axial position, and Keyphasor reference measurements on fluid-film bearing machines such as steam turbines, compressors, and pumps. It is ideal for applications requiring rugged probe construction and full interchangeability without bench calibration, meeting API 670 standards for mechanical configuration and temperature stability.
System Compatibility & Alternative Models
- System Compatibility: Fully compatible with Bently Nevada 3300 XL Proximitor Sensors and 3300 XL Extension Cables. It is completely interchangeable with non-XL 3300 series 5mm and 8mm transducer system components and fully complies with API 670 standards.
- Alternative Model: 330101-00-20-05-02-00
- Key Differences: The 330102-00-20-05-02-00 model comes equipped with a flexible AISI 302 or 304 stainless steel armor sleeve with an outer FEP jacket over its leading cable to safeguard against physical impact, abrasion, and tear hazards. Conversely, the 330101-00-20-05-02-00 is an unarmored model variant that features a bare triaxial FEP jacket, making it lighter and optimized exclusively for installations inside protected conduit paths.
Ordering Information
|
Model Series |
Option A: Unthreaded Length |
Option B: Overall Case Length |
Option C: Total Length |
Option D: Connector and Cable-Type |
Option E: Agency Approval |
|
330102 (3/8-24 UNF, with armor) |
00 (0.0 in) |
20 (2.0 in) |
05 (0.5 meter / 1.6 feet) |
02 (Miniature coaxial ClickLoc connector, standard cable) |
00 (Not required / Standard) |
Installation & Troubleshooting FAQ
Q1: What is the correct gap voltage for setting up this 3300 XL 8mm proximity probe?
A: For a standard 3300 XL 8mm proximity transducer system calibrated to AISI 4140 steel, the correct initial calibration voltage is -10.0 VDC. This voltage corresponds to the physical midpoint of the sensor's 2.0 mm (80 mils) linear range. To set this up in the field, connect a digital multimeter to the Proximitor sensor's OUT and COM terminals, then slowly rotate the probe into the mounting thread until the multimeter reads -10.0 VDC before tightening the locknut.
Q2: What is the recommended torque specification for installing this 3/8-24 UNF standard forward-mounted probe?
A: When installing this standard forward-mounted probe case into its tapped bracket, the recommended field torque is 11.2 N·m (100 in·lbf), and you must never exceed the absolute maximum rated limit of 33.9 N·m (300 in·lbf). Overtightening can permanently bind the threads or cause mechanical fracturing of the internal electronics housed within the molded polyphenylene sulfide (PPS) tip assembly.
Q3: My proximity sensor signal glitches or drifts during heavy rain or oil washdowns. How can I fix this?
A: This issue points directly to moisture ingress or oil mist contamination inside the coaxial ClickLoc connectors. The golden connection junction between the probe leading cable and the extension cable is highly vulnerable to conductive fluids. To fix and permanently prevent this, always utilize the original Bently Nevada silicone connector protectors, or tightly seal the junction using self-fusing waterproof rubber tape wrapped with an outer layer of electrical PVC tape. Note that silicone tape is not recommended if the connection is exposed directly to turbine oil.
Accessories
| 141078 | 3300 XL 8 mm and 3300 5 mm Proximity Transducer System Manual. |
| 175751 | 3300 XL Multi-Purpose Stainless Steel Housing. 12”x12”x6”. Can hold up to 8 Proximitor Sensors in a DIN-mount configuration or 6 Proximitor Sensors in a panelmount configuration. (Available with ATEX Zone 0 and Zone 1 certifications.) |
| 176467 | 3300 XL Multi-Purpose Stainless Steel Housing. 12”x8”x6”. Can hold up to 4 3300XL Proximitor Sensors in both DIN-mount and panel-mount configurations. (Available with ATEX Zone 0 and Zone 1 certifications.) |
| 330181 | 3300 XL Multi-Purpose Stainless Steel Housing. 13”x9.5”x7”. Can hold up to 8 Proximitor sensors in a DIN-mount configuration or 6 Proximitor Sensors in a panelmount configuration. Primarily used by customers requiring hazardous area approvals fro their installations. Available with ATEX Zone 0 and Zone 1 and North American Division 1 and Division 2 certifications. |
| 02120015 | Bulk field wire. 1.0 mm2 (18 AWG), 3 conductor, twisted, shielded cable with drain wire. Specify length in feet. |
| 138492-01 | Replacement panel-mount mounting pad. |
| 138493-01 | Replacement DIN-mount mounting pad. |
| 148722-01 | 3300 XL test plug. The 3300 XL Test Plug contains 3 small test pins attached to 3 color-coded 1-meter wires, each terminated in a banana plug. The 3-pin adapter plugs into the test pin holes on 3300 XL-style Proximitor sensors. You can use this test plug to check the performance of the Proximitor sensor from the test pin holes in the terminal strip without removing the field wiring. |
| 04310310 | 3300 XL Proximitor Sensor panelmount screw. One 6-32 UNC thread forming mounting screw. Four screws are required for each Proximitor sensor. (Screws supplied standard with Proximitor housings [3300 XL panel-mount option]). |
| 03200006 | Silicone self-fusing tape. A 9.1- meter (10-yard) roll of silicone tape to protect connectors. This tape is easy to install and provides excellent electrical isolation and protection from the environment. We do not recommend using this tape inside the casing of the machine. |
| 40113-02 | Connector Protector Kit. Connector Protector Kit for 3300 XL 8 mm probes and extension cables, including connector protectors and installation tools. |
| 136536-01 | Connector protector adapter. This allows you to use connector protector installation tools manufactured prior to 1998 with 75Ω ClickLoc connectors. |
| 40180-02 | Connector protectors. Package contains 10 pairs of connector protectors for 3300 XL 8 mm probes and extension cables. |
| 03839410 | 75Ω triaxial male connector protector. Male connector protectors install onto the extension cable and attach to the female connector protector on the probe, providing environmental protection of connectors. |
| 03839420 | 75Ω triaxial female connector protector. Female connector protectors install onto the probe lead and attach to the male connector protector on the extension cable, providing environmental protection of connectors. You can also place the connector protector onto the extension cable to slide over the connection to the Proximitor sensor to protect that connection from the environment. |
| 04301007 | 3/8-24 probe lock nut with safety wire holes. Single probe lock nut with 2 holes drilled through the nut in order to secure the lock nut in place with safety wire. |
| 04301008 | M10 x 1 probe lock nut with safety wire holes. Single probe lock nut with 2 holes drilled through the nut in order to secure the lock nut in place with safety wire. |
| 330153-01 | 3300 XL connector kit. Used on 3300 XL 8 mm probes and extension cables. Contains 1 pair each of male and female ClickLoc connectors, 2 colorcoded sleeves, 2 pieces of slit FEP tubing, and 1 strip of silicone tape. |
| 330153-09 | 3300 XL ETR Connector Kit. Used on ETR 3300 XL 8mm probes and 3300 ETR XL extension cables. Contains one pair of male and female ClickLoc connectors, two color-coded sleeves, two pieces of high temperature slit FEP tubing, and one strip of silicon tape. |
| 163356 | Connector Crimp Tool Kit. Includes 1 set of multiconnector inserts and connector installation instructions. Compatible only with 330153 connector kits or with probes shipped in 2003 or later with ClickLoc connectors uninstalled. Supplied with carrying case. |




For the quick assistance message us on WhatsApp at 