330101-00-26-05-01-05 is a Bently Nevada eddy current application module featuring a 2.6-inch overall case length and a compact 0.5-meter integrated cable. Fully compatible with 3/8-24 UNF mounting threads, this unit works seamlessly with hazardous-area Proximitor sensors to deliver flexible machinery diagnostics, an integrated pre-installed connector protector, and stable industrial overspeed or vibration monitoring.
Specifications
Probe Tip Materia:Polyphenylene sulfide (PPS).
Probe Case Material:AISI 303 or 304 stainless steel (SST).
Standard cable:75Ω triaxial, fluoroethylene propylene (FEP) insulated probe cable in the following total probe lengths: 0.5, 1, 1.5, 2, 3, 5, or 9 meters.
Extended Temperature Range cable:75Ω triaxial, perfluoroalkoxy(PFA) insulated probe cable in the following total probe lengths: 0.5, 1, 1.5, 2, 5, or 9 meters
Tensile Strength (MaximumRated):330 N (75 lbf) probe case to probe lead. 270 N (60 lbf) at probe lead to extension cable connectors.
Connector Material:Gold-plated brass or goldplated beryllium copper.
Standard Probe:-52°C to +177°C (-62°F to +350°F)
Extended Temperature Range Probe:-52°C to +218°C (-62°F to +425°F) for the probe tip; -51°C to +260°C (-60°F to+500°F) for the probe cable and connector.
Installation & Wiring
- Mechanical Threading: Thread the 3/8-24 UNF-2A probe body directly into the machine casing bracket until reaching the intended measuring gap.
- Locknut Tensioning: Torque the dual locknuts to the recommended 11.2 N•m (100 in•lbf) rating to maintain permanent positioning balance under continuous vibration.
- Connector Connection: Interlock the gold-plated male ClickLoc coaxial connector with the female extension cable end until an audible click confirms connection.
- Protector Alignment: Slide the pre-installed fluorosilicone connector protector housing over the joined junction path to prevent fluid contaminants from bridging the line.
- Field Component Wiring: Connect the three-conductor shielded triad field cable to the corresponding Proximitor sensor terminal block strips using the tool-free SpringLoc mechanisms.
Ordering Information
|
Option Code |
Parameter Block Description |
Configured Value Specification |
|
330101 |
Probe Model Base |
3300 XL 8mm Probe, 3/8-24 UNF thread, without armor |
|
-00 |
Unthreaded Length |
0.0 inches (Fully threaded case body) |
|
-26 |
Overall Case Length |
2.6 inches total case envelope |
|
-05 |
Total Cable Length |
0.5 meter (1.6 feet) integrated lead |
|
-01 |
Connector & Cable Type |
Miniature coaxial ClickLoc connector with connector protector, standard cable |
|
-05 |
Agency Approval Option |
CSA, ATEX, IECEx Approvals for hazardous locations |
FAQ
Q1: What is the Bently Nevada 330101-00-26-05-01-05 used for?
A1: It is used for non-contact vibration and position measurement in fluid-film bearing machines.
Q2: How does this transducer system measure distance?
A2: It outputs a voltage proportional to the gap between the probe tip and the conductive surface.
Q3: Is this model compliant with industry standards?
A3: Yes, it fully complies with API 670 for accuracy, linear range, and temperature stability.
Q4: Can components be interchanged easily?
A4: Yes, probes, cables, and sensors are fully interchangeable without recalibration.
Q5: What design features improve durability?
A5: It includes TipLoc and CableLoc technologies, ensuring strong bonding and high pull strength.
Accessories
| 141078 | 3300 XL 8 mm and 3300 5 mm Proximity Transducer System Manual. |
| 175751 | 3300 XL Multi-Purpose Stainless Steel Housing. 12”x12”x6”. Can hold up to 8 Proximitor Sensors in a DIN-mount configuration or 6 Proximitor Sensors in a panelmount configuration. (Available with ATEX Zone 0 and Zone 1 certifications.) |
| 176467 | 3300 XL Multi-Purpose Stainless Steel Housing. 12”x8”x6”. Can hold up to 4 3300XL Proximitor Sensors in both DIN-mount and panel-mount configurations. (Available with ATEX Zone 0 and Zone 1 certifications.) |
| 330181 | 3300 XL Multi-Purpose Stainless Steel Housing. 13”x9.5”x7”. Can hold up to 8 Proximitor sensors in a DIN-mount configuration or 6 Proximitor Sensors in a panelmount configuration. Primarily used by customers requiring hazardous area approvals fro their installations. Available with ATEX Zone 0 and Zone 1 and North American Division 1 and Division 2 certifications. |
| 02120015 | Bulk field wire. 1.0 mm2 (18 AWG), 3 conductor, twisted, shielded cable with drain wire. Specify length in feet. |
| 138492-01 | Replacement panel-mount mounting pad. |
| 138493-01 | Replacement DIN-mount mounting pad. |
| 148722-01 | 3300 XL test plug. The 3300 XL Test Plug contains 3 small test pins attached to 3 color-coded 1-meter wires, each terminated in a banana plug. The 3-pin adapter plugs into the test pin holes on 3300 XL-style Proximitor sensors. You can use this test plug to check the performance of the Proximitor sensor from the test pin holes in the terminal strip without removing the field wiring. |
| 04310310 | 3300 XL Proximitor Sensor panelmount screw. One 6-32 UNC thread forming mounting screw. Four screws are required for each Proximitor sensor. (Screws supplied standard with Proximitor housings [3300 XL panel-mount option]). |
| 03200006 | Silicone self-fusing tape. A 9.1- meter (10-yard) roll of silicone tape to protect connectors. This tape is easy to install and provides excellent electrical isolation and protection from the environment. We do not recommend using this tape inside the casing of the machine. |
| 40113-02 | Connector Protector Kit. Connector Protector Kit for 3300 XL 8 mm probes and extension cables, including connector protectors and installation tools. |
| 136536-01 | Connector protector adapter. This allows you to use connector protector installation tools manufactured prior to 1998 with 75Ω ClickLoc connectors. |
| 40180-02 | Connector protectors. Package contains 10 pairs of connector protectors for 3300 XL 8 mm probes and extension cables. |
| 03839410 | 75Ω triaxial male connector protector. Male connector protectors install onto the extension cable and attach to the female connector protector on the probe, providing environmental protection of connectors. |
| 03839420 | 75Ω triaxial female connector protector. Female connector protectors install onto the probe lead and attach to the male connector protector on the extension cable, providing environmental protection of connectors. You can also place the connector protector onto the extension cable to slide over the connection to the Proximitor sensor to protect that connection from the environment. |
| 04301007 | 3/8-24 probe lock nut with safety wire holes. Single probe lock nut with 2 holes drilled through the nut in order to secure the lock nut in place with safety wire. |
| 04301008 | M10 x 1 probe lock nut with safety wire holes. Single probe lock nut with 2 holes drilled through the nut in order to secure the lock nut in place with safety wire. |
| 330153-01 | 3300 XL connector kit. Used on 3300 XL 8 mm probes and extension cables. Contains 1 pair each of male and female ClickLoc connectors, 2 colorcoded sleeves, 2 pieces of slit FEP tubing, and 1 strip of silicone tape. |
| 330153-09 | 3300 XL ETR Connector Kit. Used on ETR 3300 XL 8mm probes and 3300 ETR XL extension cables. Contains one pair of male and female ClickLoc connectors, two color-coded sleeves, two pieces of high temperature slit FEP tubing, and one strip of silicon tape. |
| 163356 | Connector Crimp Tool Kit. Includes 1 set of multiconnector inserts and connector installation instructions. Compatible only with 330153 connector kits or with probes shipped in 2003 or later with ClickLoc connectors uninstalled. Supplied with carrying case. |







For the quick assistance message us on WhatsApp at 