SIMATIC S7-400 · CPU 413-2 DP
S7-400 central processing unit with MPI and integrated PROFIBUS DP communication.
Siemens 6ES7413-2XG02-0AB0 is a SIMATIC S7-400 CPU 413-2 DP central processing unit. Siemens technical documentation confirms 72 KB work memory, an MPI interface and an integrated PROFIBUS DP interface. The DP interface supports transmission rates up to 12 Mbaud and up to 64 DP stations, with documented input and output user-data areas. This older CPU requires careful project-led replacement. Procurement teams should verify the complete suffix, rack and power-supply arrangement, hardware version, memory card, MPI address, PROFIBUS role, bus parameters, STEP 7 hardware configuration and readable product-label evidence before approval.
| Product Condition | Original new |
|---|---|
| Availability | In stock |
| Official Verification | Exact order code confirmed in Siemens technical documentation |
| Warranty | With 1 year warranty |
| Shipping | Worldwide shipping options available |
Condition, availability and warranty are Stockoems commercial information, not manufacturer commitments.
| Manufacturer | Siemens |
|---|---|
| Complete Part Number | 6ES7413-2XG02-0AB0 |
| Product Type | SIMATIC S7-400 central processing unit |
| Product Designation | CPU 413-2 DP |
| Work Memory | 72 KB |
| Integrated Load Memory | 4 KB |
| Pluggable Load Memory | Up to 16 MB |
| Interfaces | MPI and PROFIBUS DP |
| Maximum DP Rate | 12 Mbaud |
| Maximum DP Stations | 64 |
| DP Input User Data | Up to 2 KB |
| DP Output User Data | Up to 2 KB |
| Digital Address Capacity | Up to 16,384 inputs and 16,384 outputs |
| Analog Address Capacity | Up to 1,024 inputs and 1,024 outputs |
| System Family | SIMATIC S7-400 |
| Country of Origin | Germany |



| S7-400 Central Control | Executes automation logic in a compatible S7-400 rack and power environment. |
|---|---|
| MPI Engineering Access | Supports configured programming, operator and S7 communication over MPI. |
| PROFIBUS DP Control | Coordinates configured distributed I/O stations through the integrated DP interface. |
| Maintenance Replacement | Requires matching rack, memory, hardware version and STEP 7 project configuration. |
Match every character in 6ES7413-2XG02-0AB0 with the installed CPU label.
Verify S7-400 rack, slot, power supply and backplane requirements.
Check hardware version, firmware information and the installed memory card.
Confirm MPI address, communication partners and engineering access.
Review master or slave role, bus address, baud rate, connectors, termination and station list.
Request readable front, rear, label, interface, memory and packaging photos.
Siemens technical documentation confirms the exact CPU 413-2 DP order code and interface architecture. The reviewed official document does not state a lifecycle category, so no unsupported lifecycle conclusion is added.
It identifies the SIMATIC S7-400 CPU 413-2 DP central processing unit.
Siemens documents an MPI interface and an integrated PROFIBUS DP interface.
The official technical information specifies 72 KB of work memory.
The reviewed Siemens technical document confirms the exact model but does not state a lifecycle category.
Verify the suffix, rack, power, hardware version, memory card, MPI and DP parameters and STEP 7 project.
Send us the complete part number, required quantity, destination country and product label photos. Our team will check availability, condition, compatibility requirements and shipping options.
Email: sales6@apterpower.com | WhatsApp: +86 18159889985
STOCKOEMS PROCUREMENT SUPPORT
Identity control, compatibility review, documented inspection, protective packaging and coordinated international logistics.
| 01 | Model and suffix verification | The complete article number and every suffix character are checked against order records and label evidence. |
|---|---|---|
| 02 | Condition confirmation | Housing, labels, interfaces, connectors and supplied accessories are reviewed. |
| 03 | Technical compatibility review | S7-400 rack, power supply, hardware version, memory, MPI data, PROFIBUS DP parameters and STEP 7 project are compared. |
| 04 | Product and label photo confirmation | Readable front, rear, nameplate, connector and packaging photos can be requested. |
| 05 | Protective packaging | The product body, interfaces, connectors and supplied accessories are protected for handling and transport. |
| 06 | Worldwide shipping | Available routes are coordinated without promising an unconfirmed delivery date. |
| 07 | Shipment tracking | Tracking information is shared after carrier acceptance. |
| 08 | Customs documentation | Commercial shipment documents are prepared for the confirmed order and destination. |
| 09 | Written warranty terms | Warranty scope is recorded in Stockoems commercial documents. |
| 10 | Return authorization process | Returns require written authorization and review under the agreed commercial terms. |
| 11 | After-sales response | Post-shipment questions are handled with order, label, wiring and installation evidence. |
Check whether the supplier verifies the complete suffix, provides readable label and condition photos, discusses compatibility limits, records warranty and return terms, protects the equipment and supplies traceable shipment documents.
Warning signs include blurred labels, substituted suffixes, unsupported parameter claims, unclear condition descriptions, missing inspection evidence, unrecorded return terms and payment requests that do not match the stated company identity.
Email: sales6@apterpower.com | WhatsApp: +86 18159889985
| AMG 2151 | 64-825-0045-4 | AN100 | 4744R | 4743 |
| 1-XR4-433C | T6831A | SM322 32DO 6AG1322-1BL00-2AA0 | ABB MT701.2 | S7-300 SM321 6AG1321-1BL00-2AA0 |
| VFI2 | DT100FM151 | 0635.1044/404B | ZHCL-3-24/48V | 140DDO35300 |
| 1900071071 | B501 | ME96SSE-MB | FA-2016E1 | CL06A300M1 |
| RM35TF30 | 51305437-100 | AN-3100D | M-ME-C205.40 | 8003/20-3-1 |
| M-ME-C202.32 | M-ME-M204.32 | M-AF-M210.04 | 7P016XL | MS-FEC2611-0 |
| PAD-4-MB | M-ME-D204-12 | IN1606 | 330180-91-05 | FSDDR0322 F400 |
| SDU101 F004 | ABB TB820V2 3BSE013208R1 | IQE31-1201U50034 | DG-11 DGC11-3PK-6500T | DES-12-G DES-12 G 3PK-6500T |
| BMS-2N-24D D2003ACWR-DBY | AT-HDTX-IR | XPSAF5130 | ABB 6125/01-83-500 | tya604d |
| Xenta 412 | EX310 | S701 | EL3164 | OGP502 |
| QAX34.1 | NS-ATA7003-0 | DVP04PT-H2 | PRFB-A | TR2D09310 |
| TR2D32355 | 505C633G01 A200 | PT-SFP-GE-L | TD3RCBO | E6173A |
| E1411B | JDB1610 | ZZ-135-U02 | QSA224DC SCA068 | MTL4546Y |
| XCKM121 | 1F83-71 2 | BB-2000L | SC-MD04250 | URX-P2 |
Email: sales6@apterpower.com | WhatsApp: +86 18159889985