330103-00-06-50-02-05 Product datasheet
Model number: |
330103-00-06-50-02-05 |
|
Module Type: |
3300 XL 8 mm Proximity Probes |
Manufacture: |
Bently Nevada |
|
Condition: |
Brand New |
Range of Product: |
3300 System |
|
Lead time: |
In Stock |
Weight: |
0.15 kg |
|
HS CODE: |
8537101190 |
Dimension: |
20.5x22.4×3.3cm |
|
MOQ: |
1 |
Product Origin: |
USA |
|
System: |
TSI |
Discontinued on: |
active |
|
Communication Service: |
Ethernet router |
330103-00-06-50-02-05 Functional Description
If you have other request contact our team to get customized service
Bently Nevada |
990-04-50-01-00 |
Bently Nevada |
190501-15-99-00 |
Bently Nevada |
190501-00-99-01 |
Bently Nevada |
990-04-50-01-01 |
Bently Nevada |
190501-16-99-00 |
Bently Nevada |
190501-01-99-01 |
Bently Nevada |
990-04-50-02-01 |
Bently Nevada |
190501-17-99-00 |
Bently Nevada |
190501-03-99-01 |
Bently Nevada |
990-04-50-03-00 |
Bently Nevada |
190501-18-99-00 |
Bently Nevada |
190501-22-99-01 |
Bently Nevada |
990-05-50-03-00 |
Bently Nevada |
190501-19-99-00 |
Bently Nevada |
190501-04-99-01 |
Bently Nevada |
990-05-50-03-01 |
Bently Nevada |
190501-20-99-00 |
Bently Nevada |
190501-05-99-01 |
Bently Nevada |
990-05-70-01-00 |
Bently Nevada |
190501-21-99-00 |
Bently Nevada |
190501-07-99-01 |
Bently Nevada |
190501-01-99-04 |
Bently Nevada |
190501-22-99-00 |
Bently Nevada |
190501-06-99-01 |
Bently Nevada |
190501-23-99-01 |
Bently Nevada |
190501-23-99-00 |
Bently Nevada |
190501-08-99-01 |
Bently Nevada |
190501-02-99-01 |
Bently Nevada |
190501-24-99-00 |
Bently Nevada |
190501-09-99-01 |
3300 XL 8 mm Proximity Transducer System Datasheet
3300 XL 8 mm components are both electrically and physically interchangeable with non-XL 3300 5 mm and 8 mm components. Although the packaging of the 3300 XL Proximitor Sensor differs from its predecessor, its design fits in the same 4-hole mounting pattern when used with the 4-hole mounting base, and will fit within the same mounting space specifications (when minimum permissible cable bend radius is observed). Mixing XL and non-XL 3300-series 5 mm and 8 mm system components limits system performance to the specifications for the nonXL 3300 5 mm and 8 mm Transducer System.8 mm probes provide a thicker encapsulation of the probe coil in the molded PPS plastic probe tip. This results in a more rugged probe. The larger diameter of the probe body also provides a stronger, more robust case. We recommend that you use 8 mm probes when possible to provide optimal robustness against physical abuse.