05704-A-0123 Product datasheet
Model number: |
05704-A-0123 |
|
Module Type: |
Hex Relay Interface Card |
Manufacture: |
HONEYWELL |
|
Condition: |
Brand New |
Range of Product: |
Experion PKS |
|
Lead time: |
In Stock |
Weight: |
0.22 kg |
|
HS CODE: |
8537101190 |
Dimension: |
2.3×11.8×13cm |
|
MOQ: |
1 |
Product Origin: |
USA |
|
System: |
DCS |
Discontinued on: |
active |
|
Communication Service: |
Ethernet router |
05704-A-0123 Functional Description
If you have other request contact our team to get customized service
Honeywell |
05704-A-0145 |
Honeywell |
51202324-100 |
Honeywell |
MC-TAMT03 51309223-175 |
Honeywell |
05704-A-0123 |
Honeywell |
MU-TAMT02 51401491-100 |
Honeywell |
MC-TAMR04 51305907-175 |
Honeywell |
05704-A-0121 |
Honeywell |
MU-TAMR03 51309218-125 |
Honeywell |
MC-TAMR03 51309218-175 |
Honeywell |
05701-A-0361 |
Honeywell |
MU-TAIH12 51304337-100 |
Honeywell |
MC-TAIH22 51204170-250 |
Honeywell |
05701-A-0302 |
Honeywell |
MU-TAIH02 51304453-100 |
Honeywell |
MC-TAIH14 51305887-150 |
Honeywell |
51202329-402 |
Honeywell |
MC-TAOY22 51204172-175 |
Honeywell |
MC-TAIH12 51304337-150 |
Honeywell |
51202329-202 |
Honeywell |
MC-TAOX52 51304335-275 |
Honeywell |
MC-TAIH04 51305900-175 |
Honeywell |
51202329-200 |
Honeywell | MC-PRHM01 51404109-175 | Honeywell | MC-PLAM02 51304362-150 |
Honeywell | 51202329-112 |
Honeywell |
MC-TAOX12 51304335-175 |
Honeywell |
MC-TAIH02 51304453-150 |
Honeywell |
51202324-300 |
Honeywell |
MC-TAMT04 51305890-175 |
Honeywell |
MC-PSIM11 51304362-350 |
5704F Fire Control Card
The 5704F Four Channel Fire Control Card provides control, display and alarm facilities for up to four separate loops (or zones) of fire detection. Depending upon the type of detector each loop may have more than one detector. The card also provides two fault monitored switched dc outputs and a minimum of six volt free outputs. The front panel uses clear LED displays to indicate the status of all input and output loops and card status. A push-button is provided for selecting the card for use with the Fire Status Panel and Engineering Card. The operation of the control card is microprocessor controlled and is fully definable for a wide range of connected fire detectors and application requirements. The setup information is stored in a non-volatile memory on the fire card. A number of user selectable jumper links are also provided for compatibility with some system requirements. The single fire card covers all common applications, no other plug-in modules are required.