Honeywell RC500 RTU RC-SCONTRL Remote Terminal Unit

Honeywell RC500 RTU RC-SCONTRL
Honeywell RC500 RTU RC-SCONTRL
Honeywell RC500 RTU RC-SCONTRL

RC500 RTU RC-SCONTRL Product datasheet 

Model number:

RC500 RTU RC-SCONTRL

 

Module Type:

Remote Terminal Unit

Manufacture:

HONEYWELL

 

Condition:

Brand New

Range of Product:

MU-T Series

 

Lead time:

In Stock

Weight:

0.82 kg

 

HS CODE:

8537101190

Dimension:

3x31.2x27.8cm

 

MOQ:

1

Product Origin:

USA

 

System:

DCS

Discontinued on:

active

 

Communication Service:

Ethernet router

 

RC500 RTU RC-SCONTRL Functional Description


The Remote Terminal Unit RC500 RTU RC-SCONTRL Honeywell is a modular, scalable remote terminal unit designed for demanding industrial automation applications. This robust controller combines with Honeywell's SCADA systems to deliver integrated solutions for complex remote monitoring and control tasks. The Honeywell RC500 RTU RC-SCONTRL offers flexible configuration options, supporting both non-redundant and redundant setups to meet diverse operational requirements. Built on an embedded Linux platform, it provides reliable performance in harsh environments while seamlessly integrating with Experion control systems through industry-standard protocols like Modbus and DNP3.

 

Featuring adaptable I/O expansion options, the Control Unit  RC500 RTU RC-SCONTRL supports DIN rail-mountable modules that enable hot swapping for maintenance and upgrades. Its Ethernet I/O modules facilitate easy configuration and self-calibration, with a comprehensive range available for different application needs. The Honeywell RC500 RTU RC-SCONTRL Remote Terminal Unit stands out for its protocol flexibility, allowing customization based on communication port requirements, memory needs, and system topology. This versatility makes it ideal for oil/gas, water distribution, and power sector applications requiring reliable remote automation.

 

The RC500 RTU RC-Honeywell advanced industrial control is supported by specialized engineering tools including the RC500 I/O Toolkit for configuration and ISAGRAF software for advanced programming. This combination provides full IEC 61131-3 standard compliance, offering all five programming languages: Ladder Diagram, Structured Text, Function Block Diagram, Instruction List, and Sequential Function Chart. The Honeywell RC500 RTU RC-SCONTRL's development environment enables efficient creation of custom control strategies while maintaining system integrity and security.

 

As a key component in modern SCADA systems, the RC500 RTU RC-SCONTRL HONEYWELL delivers critical automation capabilities for remote sites. Its ability to handle complex control algorithms while maintaining communication with central Experion systems makes it invaluable for distributed operations. The unit's rugged design, combined with Honeywell's engineering expertise, ensures long-term reliability in mission-critical infrastructure applications where uninterrupted operation is essential.

If you have other request contact our team to get customized service


  •       One Year Warranty

    We offer a one-year warranty for any quality issues with our products. If you encounter any defects or malfunctions during this period, please contact us for prompt resolution. Our warranty covers repairs or replacements, ensuring your satisfaction and peace of mind.

  •         Shipping & Delivery

    We have 10 years experience with leading logistics companies like FedEx, DHL, and SF, ensuring efficient and reliable shipping solutions. Our extensive experience in working with these carriers allows us to offer fast, secure delivery services, tailored to meet the diverse needs of our customers.
  • #

                Payment Method

    We accept a variety of payment methods, including T/T Bank Transfer, Alipay, and more, providing flexible options to suit our customers' preferences. This ensures a convenient and secure transaction process for all orders.
 
How Can I Get Your Support?
Call +86 18159889985 to be connected with our Manager Stella
     Email to sales6@apterpower.com get your best quotation
    For the quick assistance message us on WhatsApp at +86 18159889985 now!
    You can also reach me via Skype: live:ariatang111 or WeChat: zxd18159889985!
 

 

Honeywell

DC-TAOX11

Honeywell

FC-PSU-UNI2450U V1.0

Honeywell

DCOM-232/485 FC-DCOM-232/485

Honeywell

DC-TDIL61   

Honeywell

CC-TFB412 51308311-275

Honeywell

DC-TAIL51 51307601-176

Honeywell

DC-TDOD61

Honeywell

CC-TAON01 51306519-175

Honeywell

DC-TAIX01 51307597-176

Honeywell

FS-SDIL-1608

Honeywell

CC-TAOX11 51308353-175

Honeywell

DC-TCF901 51307593-176

Honeywell

FS-SDO-0824

Honeywell

CC-TCF901 51308301-175

Honeywell

DC-TFB402  51307616-176

Honeywell

CC-TCF901 

Honeywell

CC-TDIL01 51308386-175

Honeywell

CC-TAID11 51306731-175

Honeywell

CC-TFB412

Honeywell

CC-TDIL11 51308388-175

Honeywell

CC-TDOB11 51308373-175

Honeywell

FC-TSDO-04UNI

Honeywell

CC-TDOB11 51308373-175

Honeywell

CC-PDOB11 51308373-175

Honeywell

51153818-202

Honeywell

FC-TSRO-0824 V1.1

Honeywell

CC-PDOB01 51405043-176

Honeywell

51153818-201

Honeywell

FC-TSHART-1620M

Honeywell

CC-PDOB01 51405043-175

 

RTU Configuration and Network Setup


The Honeywell RC500 RTU RC-SCONTRL requires initial configuration through the dedicated RC500 I/O Tool Kit, where engineers create project files (.6pj extension) containing all RTU and I/O module parameters. Each RC-SCONTRL unit features two independent Ethernet ports (Port 1 and Port 2) with unique MAC addresses, designed for operation on separate networks. Critical to installation is proper IP address assignment - both ports must be configured on distinct Ethernet networks with individual subnet masks, as simultaneous operation on the same network triggers automatic port disabling by the RTU's operating system, potentially causing operational disruptions. The configuration process involves defining communication parameters, I/O module assignments, and network topology while ensuring redundant network paths maintain complete isolation. This dual-port architecture provides network redundancy and failover capabilities when properly implemented, a key feature for mission-critical SCADA applications. Engineers must carefully plan the IP addressing scheme during initial setup to leverage the RC-SCONTRL's full network reliability features while avoiding the performance issues that arise from incorrect network configuration. The Tool Kit's intuitive interface guides users through these critical setup steps while maintaining system integrity.

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit

Need Help? Chat with us

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit
Looking for News&Events?
Contact Us #
+8618159889985

Our hours

Mon 11/21 - Wed 11/23: 9 AM - 8 PM
Thu 11/24: closed - Happy Thanksgiving!
Fri 11/25: 8 AM - 10 PM
Sat 11/26 - Sun 11/27: 10 AM - 9 PM
(all hours are Eastern Time)

Home

Products

whatsApp

contact