3500/77M-03-00 143729-01 Product datasheet
Model number: |
3500/77M-03-00 143729-01 |
|
Module Type: |
Cylinder Pressure I/O with Internal Terminations |
Manufacture: |
Bently Nevada |
|
Condition: |
Brand New |
Range of Product: |
3500 system |
|
Lead time: |
In Stock |
Weight: |
0.38 kg |
|
HS CODE: |
8537101190 |
Dimension: |
2.3x11x24.1cm |
|
MOQ: |
1 |
Product Origin: |
USA |
|
System: |
TSI |
Discontinued on: |
active |
|
Communication Service: |
Ethernet router |
3500/77M-03-00 143729-01 Functional Description
If you have other request contact our team to get customized service
Bently Nevada |
133300-01 |
Bently Nevada |
288062-02 |
Bently Nevada |
3500/61 136711-02 |
Bently Nevada |
135031-01 |
Bently Nevada |
128276-01E |
Bently Nevada |
3500/60 163179-01 |
Bently Nevada |
133434-01 |
Bently Nevada |
3500/72M 176449-08 |
Bently Nevada |
3500/60 133811-01 |
Bently Nevada |
133396-01 |
Bently Nevada |
3500/70M 176449-09 |
Bently Nevada |
3500/60 |
Bently Nevada |
133323-01 |
Bently Nevada |
3500/77M-03-00 176449-07 |
Bently Nevada |
3500/54M 286566-01 |
Bently Nevada |
125744-01 |
Bently Nevada |
3500/64M 176449-05 |
Bently Nevada |
3500/53 133388-01 |
Bently Nevada |
149992-03 |
Bently Nevada |
3500/77M-03-00 143729-01 |
Bently Nevada |
3500/50M 286566-02 |
Bently Nevada |
149992-04 |
Bently Nevada |
3500/62 163179-03 |
Bently Nevada |
3500/20 125744-02 |
Bently Nevada |
126623-01 |
Bently Nevada |
3500/61E 285694-02 |
Bently Nevada |
3500/15 133292-01 |
Bently Nevada |
128718-01 |
Bently Nevada |
3500/61 163179-02 |
Bently Nevada |
3500/15 129486-01 |
3500/77M Recip Cylinder Pressure Monitor
The 3500/77M Recip Cylinder Pressure Monitor is a 4-channel monitor that accepts input from Bently Nevada approved pressure transducers, conditions the signal to make various pressure measurements for reciprocating compressors, and compares the conditioned signals with user-programmable alarms.
The primary purpose of the 3500/77M monitor is to provide:
• Machinery protection by continuously comparing monitored parameters against configured alarm setpoints to drive alarms.
• Essential machine information for both operations and maintenance personnel.
Depending on configuration, each channel typically conditions its input signal to provide various parameters called “proportional values,” also referred to as PPL’s. Users can configure Alert setpoints for each active proportional value (PPL) and Danger setpoints for any two of the active proportional values.