3500/33-04-00 149992-04 Functional Description
If you have other request contact our team to get customized service
Bently Nevada |
133300-01 |
Bently Nevada |
128277-01C |
Bently Nevada |
3500/61 136711-02 |
Bently Nevada |
135031-01 |
Bently Nevada |
128276-01E |
Bently Nevada |
3500/60 163179-01 |
Bently Nevada |
133434-01 |
Bently Nevada |
3500/72M 176449-08 |
Bently Nevada |
3500/60 133811-01 |
Bently Nevada |
133396-01 |
Bently Nevada |
3500/70M 176449-09 |
Bently Nevada |
3500/60 |
Bently Nevada |
133323-01 |
Bently Nevada |
3500/65 145988-02 |
Bently Nevada |
3500/54M 286566-01 |
Bently Nevada |
125744-01 |
Bently Nevada |
3500/64M 176449-05 |
Bently Nevada |
3500/53 133388-01 |
Bently Nevada |
149992-03 |
Bently Nevada |
3500/64M |
Bently Nevada |
3500/50M 286566-02 |
Bently Nevada |
149992-04 |
Bently Nevada |
3500/62 163179-03 |
Bently Nevada |
3500/20 125744-02 |
Bently Nevada |
129478-01 |
Bently Nevada |
3500/61E 285694-02 |
Bently Nevada |
3500/15 133292-01 |
Bently Nevada |
128718-01 |
Bently Nevada |
3500/61 163179-02 |
Bently Nevada |
3500/15 129486-01 |
3500/33 16-Channel Relay Module Datasheet
The 3500/33 16-Channel Relay Module requires the 3500 Rack Config, version 3.3 or later.
The 3500/33 requires the 3500 Data Acquisition Software, version 2.40 or later.
The 3500/33 16-Channel Relay Module requires the 3500 Data Display Software, version 1.40 or later.
When ordered with the multiple approvals option (-02), the 3500 monitor is certified to Zone 2 standards, including ATEX and North American zones.
The Zone 2 standards specify increased spacing requirements at higher voltages. The 3500/33 16-Channel Relay Module does not meet these spacing requirements. Thus, the module ordered with the multiple approvals option is limited to a lower voltage than those with the other approvals options. Using higher voltages violates the hazardous area certificates associated with the multiple approvals option. The North American Division 2 standards associated with the CSA-only approvals option (-01) have been de-rated to 30 Vrms to comply with 61010-1 type test requirements. If the 3500/33 16-Channel Relay Module is part of a functional safety (SIL) system, the functional safety certificate requires the restricted voltage. Higher voltages are not allowed for functional safety (SIL) systems.